<?xml version="1.0" encoding="UTF-8"?>

<Specimen xmlns="http://hl7.org/fhir">
  <id value="IntegratedSLNSpecimenPart"/>
  <meta>
    <profile value="https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/StructureDefinition/mii-pr-patho-specimen|2026.0.0"/>
    <profile value="https://www.medizininformatik-initiative.de/fhir/ext/modul-biobank/StructureDefinition/SpecimenCore|2026.0.0"/>
  </meta>
  <text>
    <status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: Specimen IntegratedSLNSpecimenPart</b></p><a name="IntegratedSLNSpecimenPart"> </a><a name="hcIntegratedSLNSpecimenPart"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px"/><p style="margin-bottom: 0px">Profiles: <a href="https://simplifier.net/resolve?scope=de.medizininformatikinitiative.kerndatensatz.patho@2026.0.0&amp;canonical=https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/StructureDefinition/mii-pr-patho-specimen">MII PR Patho Specimen</a> version: 2026.0.0, <a href="https://simplifier.net/resolve?scope=de.medizininformatikinitiative.kerndatensatz.onkologie@2026.0.0&amp;canonical=https://www.medizininformatik-initiative.de/fhir/ext/modul-biobank/StructureDefinition/SpecimenCore">MII PR Biobank Specimen Bioprobe Core</a> version: 2026.0.0</p></div><p><b>identifier</b>: Placer Identifier/OP25_300_B, Filler Identifier/E_25_300_B</p><p><b>accessionIdentifier</b>: <code>https://pathologie.example-hospital.de/fhir/fn/befundbericht</code>/E_25_300</p><p><b>status</b>: Available</p><p><b>type</b>: <span title="Codes:{http://snomed.info/sct 258589002}">Lymph node specimen (specimen)</span></p><p><b>subject</b>: <a href="Patient-Patient4.html">Sabine Becker  Female, DoB: 1971-03-15 ( http://example.hospital.de/patient-ids#PAT-2025-105)</a></p><p><b>request</b>: <a href="ServiceRequest-IntegratedReportRequest.html">ServiceRequest Pathology synoptic report</a></p><h3>Collections</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Collector</b></td><td><b>Collected[x]</b></td><td><b>Method</b></td><td><b>BodySite</b></td></tr><tr><td style="display: none">*</td><td><a href="Practitioner-BreastSurgeonPractitioner.html">Practitioner Thomas Richter </a></td><td>2025-02-05 10:30:00+0100</td><td><span title="Codes:{http://snomed.info/sct 396487001}">Sentinel lymph node biopsy (procedure)</span></td><td><span title="Codes:{http://snomed.info/sct 68171009}">Axillary lymph node structure (body structure)</span></td></tr></table><h3>Containers</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Type</b></td><td><b>Additive[x]</b></td></tr><tr><td style="display: none">*</td><td><span title="Codes:{http://snomed.info/sct 434746001}">Specimen vial (physical object)</span></td><td><span title="Codes:{http://snomed.info/sct 434162003}">Neutral buffered formalin (substance)</span></td></tr></table><p><b>note</b>: </p><blockquote><div><p>Sentinel-Lymphknoten-Exzisat linke Axilla, 2 SLN identifiziert (Patentblau-markiert). SLN #1: 12 x 8 x 6 mm, SLN #2: 10 x 7 x 5 mm. Beide halbiert und vollständig eingebettet.</p>
</div></blockquote></div>
  </text>
  <identifier>
    <type>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/v2-0203"/>
        <code value="PLAC"/>
      </coding>
    </type>
    <system value="https://senologie.example-hospital.de/fhir/specimen/placer"/>
    <value value="OP25_300_B"/>
  </identifier>
  <identifier>
    <type>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/v2-0203"/>
        <code value="FILL"/>
      </coding>
    </type>
    <system value="https://pathologie.example-hospital.de/fhir/fn/befundbericht"/>
    <value value="E_25_300_B"/>
  </identifier>
  <accessionIdentifier>
    <system value="https://pathologie.example-hospital.de/fhir/fn/befundbericht"/>
    <value value="E_25_300"/>
  </accessionIdentifier>
  <status value="available"/>
  <type>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="258589002"/>
      <display value="Lymph node specimen (specimen)"/>
    </coding>
  </type>
  <subject>
    <reference value="Patient/Patient4"/>
  </subject>
  <request>
    <reference value="ServiceRequest/IntegratedReportRequest"/>
  </request>
  <collection>
    <collector>
      <reference value="Practitioner/BreastSurgeonPractitioner"/>
    </collector>
    <collectedDateTime value="2025-02-05T10:30:00+01:00"/>
    <method>
      <coding>
        <system value="http://snomed.info/sct"/>
        <code value="396487001"/>
        <display value="Sentinel lymph node biopsy (procedure)"/>
      </coding>
    </method>
    <bodySite>
      <coding>
        <system value="http://snomed.info/sct"/>
        <code value="68171009"/>
        <display value="Axillary lymph node structure (body structure)"/>
      </coding>
    </bodySite>
  </collection>
  <container>
    <type>
      <coding>
        <system value="http://snomed.info/sct"/>
        <code value="434746001"/>
        <display value="Specimen vial (physical object)"/>
      </coding>
    </type>
    <additiveCodeableConcept>
      <coding>
        <system value="http://snomed.info/sct"/>
        <code value="434162003"/>
        <display value="Neutral buffered formalin (substance)"/>
      </coding>
    </additiveCodeableConcept>
  </container>
  <note>
    <text value="Sentinel-Lymphknoten-Exzisat linke Axilla, 2 SLN identifiziert (Patentblau-markiert). SLN #1: 12 x 8 x 6 mm, SLN #2: 10 x 7 x 5 mm. Beide halbiert und vollständig eingebettet."/>
  </note>
</Specimen>