Scenario Liver Transplant Monitoring

This page shows an end-to-end example of wearable-based peri-operative vital sign monitoring in ENRICH-mHealth, using the ISiK Vitalparameter observation profiles together with the HDDT-derived Personal Health Device profile.

Clinical narrative

A 45-year-old male patient is scheduled for an orthotopic liver transplantation. To capture his physiological baseline and his post-operative recovery outside the hospital, he is equipped with a Withings ScanWatch 2 and monitored for two weeks before and two weeks after the transplantation (surgery on 2026-03-02).

Throughout both periods the wearable records arterial oxygen saturation (SpO2) and heart rate every 6 hours (four measurements per day). The pre-operative series documents a stable baseline; the post-operative series shows the expected recovery trend — a transiently reduced SpO2 that normalises and an initially elevated heart rate that settles over the two weeks.

Every measurement is captured as an Observation that references the wearable via Observation.device, so each value carries explicit device provenance back to the registered Personal Health Device.

Monitoring design

   
Device Withings ScanWatch 2 (Personal Health Device)
Parameters SpO2 (profile), heart rate (profile)
Sampling interval every 6 hours (4× / day)
Pre-op window 2026-02-16 … 2026-03-01 (56 timepoints)
Post-op window 2026-03-03 … 2026-03-16 (56 timepoints)
Total observations 56 × 2 periods × 2 parameters = 224

The full series is named Example-ENRICH-{SpO2\|HR}-LiverTx-{Pre\|Post}-01 … -56; all 224 instances are listed under FHIR Artifacts.

Timeline

Date Event Resource(s)
2026-02-16 – 2026-03-01 Pre-operative baseline monitoring, SpO2 + heart rate every 6 h SpO2 pre-op #1, Heart rate pre-op #1
2026-03-02 Orthotopic liver transplantation Liver Transplantation
2026-03-03 – 2026-03-16 Post-operative recovery monitoring, SpO2 + heart rate every 6 h SpO2 post-op #1, Heart rate post-op #1

Information model

Element Resource Example instance
Patient (45 y, male) Patient Patient
Wearable Device (Personal Health Device) Withings ScanWatch 2
Transplantation Procedure Liver Transplantation
Oxygen saturation Observation (SpO2) SpO2 pre-op #1 … -56, post-op #1 … -56
Heart rate Observation (Herzfrequenz) Heart rate pre-op #1 … -56, post-op #1 … -56
  • Device provenance: every Observation.device references the Withings ScanWatch 2 Personal Health Device.
  • Subject: all resources reference the same Patient via subject / patient.
  • Coding: each observation carries both a LOINC code and the corresponding IEEE 11073 MDC code (e.g. MDC_PULS_OXIM_SAT_O2, MDC_ECG_HEART_RATE), as inherited from the ISiK Vitalparameter profiles.