NAPKON Cardiology Module
1.0.0 - ci-build

NAPKON Cardiology Module - Local Development build (v1.0.0). See the Directory of published versions

Resource Profile: ECG Atrioventricular Block

Defining URL:https://www.napkon.de/fhir/StructureDefinition/ecg-atrioventricular-block
Version:1.0.0
Name:ECGAtrioventricularBlock
Title:ECG Atrioventricular Block
Status:Active as of 2021-11-17
Definition:

Atrioventricular block finding from electrocardiogram

Publisher:Charité - Universitätsmedizin Berlin
Source Resource:XML / JSON / Turtle

The official URL for this profile is:

https://www.napkon.de/fhir/StructureDefinition/ecg-atrioventricular-block

Guidance

This profile encodes the finding of atrioventricular blocks from electrocardiographic (ECG) recordings.

Parameter Case Report Form Response Options
Atrioventricular block First degree / Second degree / Third degree / No block / No information available

The response options are encoded as follows:

Response Option Observation.code Observation.valueBoolean Observation.dataAbsentReason
First degree First degree atrioventricular block (disorder) true -
Second degree Second degree atrioventricular block (disorder) true -
Third degree Complete atrioventricular block (disorder) true -
No block Atrioventricular block (disorder) false -
No information available Atrioventricular block (disorder) - #unknown

This profile of a FHIR Observation is derived from the Observation FHIR resource.

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation I0..*ObservationMeasurements and simple assertions
value-or-data-absent-reason: If there is no a value a data absent reason must be present or vice versa
... id Σ0..1stringLogical id of this artifact
... meta Σ0..1MetaMetadata about the resource
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
... language 0..1codeLanguage of the resource content
Binding: CommonLanguages (preferred)
Max Binding: AllLanguages: A human language.

... text 0..1NarrativeText summary of the resource, for human interpretation
... contained 0..*ResourceContained, inline Resources
... extension 0..*ExtensionAdditional content defined by implementations
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
... identifier Σ0..*IdentifierBusiness Identifier for observation
... basedOn Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
... partOf Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
... status ?!Σ1..1coderegistered | preliminary | final | amended +
Binding: ObservationStatus (required): Codes providing the status of an observation.

... category 0..*CodeableConceptClassification of type of observation
Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


... code SΣ1..1CodeableConceptType of observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

.... id 0..1stringUnique id for inter-element referencing
.... Slices for extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
.... Slices for coding Σ1..*CodingCode defined by a terminology system
Slice: Unordered, Open by pattern:$this
..... coding:sct Σ1..1CodingCode defined by a terminology system
Binding: ECG Atrioventricular Block (required)
.... text Σ0..1stringPlain text representation of the concept
... subject SΣ1..1Reference(Patient)A reference from one resource to another
... focus Σ0..*Reference(Resource)What the observation is about, when it is not about the subject of record
... encounter Σ0..1Reference(Encounter)Healthcare event during which this observation is made
... effective[x] SΣ1..1Clinically relevant time/time-period for observation
.... effectiveDateTimedateTime
.... effectivePeriodPeriod
.... effectiveTimingTiming
.... effectiveInstantinstant
... issued Σ0..1instantDate/Time this version was made available
... performer Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
... Slices for value[x] ΣI0..1booleanActual result
Slice: Unordered, Closed by type:$this
.... value[x]:valueBoolean SΣI0..1booleanActual result
... dataAbsentReason I0..1CodeableConceptWhy the result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

... interpretation 0..*CodeableConceptHigh, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


... note 0..*AnnotationComments about the observation
... bodySite 0..1CodeableConceptObserved body part
Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.


Required Pattern: At least the following
.... id0..1stringUnique id for inter-element referencing
.... extension0..*ExtensionAdditional content defined by implementations
.... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
..... id0..1stringUnique id for inter-element referencing
..... extension0..*ExtensionAdditional content defined by implementations
..... system1..1uriIdentity of the terminology system
Fixed Value: http://snomed.info/sct
..... version0..1stringVersion of the system - if relevant
..... code1..1codeSymbol in syntax defined by the system
Fixed Value: 80891009
..... display1..1stringRepresentation defined by the system
Fixed Value: Heart structure (body structure)
..... userSelected0..1booleanIf this coding was chosen directly by the user
.... text0..1stringPlain text representation of the concept
... method 0..1CodeableConceptHow it was done
Binding: ObservationMethods (example): Methods for simple observations.

... specimen 0..1Reference(Specimen)Specimen used for this observation
... device 0..1Reference(Device | DeviceMetric)(Measurement) Device
... referenceRange I0..*BackboneElementProvides guide for interpretation
obs-3: Must have at least a low or a high or text
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... low I0..1SimpleQuantityLow Range, if relevant
.... high I0..1SimpleQuantityHigh Range, if relevant
.... type 0..1CodeableConceptReference range qualifier
Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

.... appliesTo 0..*CodeableConceptReference range population
Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.


.... age 0..1RangeApplicable age range, if relevant
.... text 0..1stringText based reference range in an observation
... hasMember Σ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)Related resource that belongs to the Observation group
... derivedFrom Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence)Related measurements the observation is made from
... component Σ0..*BackboneElementComponent results
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... code Σ1..1CodeableConceptType of component observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

.... value[x] Σ0..1Actual component result
..... valueQuantityQuantity
..... valueCodeableConceptCodeableConcept
..... valueStringstring
..... valueBooleanboolean
..... valueIntegerinteger
..... valueRangeRange
..... valueRatioRatio
..... valueSampledDataSampledData
..... valueTimetime
..... valueDateTimedateTime
..... valuePeriodPeriod
.... dataAbsentReason I0..1CodeableConceptWhy the component result is missing
Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

.... interpretation 0..*CodeableConceptHigh, low, normal, etc.
Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


.... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result

doco Documentation for this format
NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation I0..*ObservationMeasurements and simple assertions
value-or-data-absent-reason: If there is no a value a data absent reason must be present or vice versa
... code Σ1..1CodeableConceptType of observation (code / type)
Binding: LOINCCodes (example): Codes identifying names of simple observations.

... subject Σ1..1Reference(Patient)A reference from one resource to another
... effective[x] Σ1..1Clinically relevant time/time-period for observation
.... effectiveDateTimedateTime
.... effectivePeriodPeriod
.... effectiveTimingTiming
.... effectiveInstantinstant

doco Documentation for this format

This structure is derived from Observation

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation I0..*ObservationMeasurements and simple assertions
value-or-data-absent-reason: If there is no a value a data absent reason must be present or vice versa
... code S1..1CodeableConceptType of observation (code / type)
.... Slices for coding 1..*CodingCode defined by a terminology system
Slice: Unordered, Open by pattern:$this
..... coding:sct 1..1CodingCode defined by a terminology system
Binding: ECG Atrioventricular Block (required)
... subject S1..1Reference(Patient)A reference from one resource to another
... effective[x] S1..1dateTime, Period, Timing, instantClinically relevant time/time-period for observation
... valueBoolean S0..1booleanActual result
... bodySite 0..1CodeableConceptObserved body part
Required Pattern: At least the following
.... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
..... system1..1uriIdentity of the terminology system
Fixed Value: http://snomed.info/sct
..... code1..1codeSymbol in syntax defined by the system
Fixed Value: 80891009
..... display1..1stringRepresentation defined by the system
Fixed Value: Heart structure (body structure)

doco Documentation for this format

This structure is derived from Observation

Summary

Mandatory: 4 elements
Must-Support: 4 elements

Structures

This structure refers to these other structures:

Slices

This structure defines the following Slices:

  • The element Observation.code.coding is sliced based on the value of pattern:$this
  • The element Observation.value[x] is sliced based on the value of type:$this

 

Other representations of profile: CSV, Excel, Schematron

Terminology Bindings

PathConformanceValueSet / Code
Observation.languagepreferredCommonLanguages
Max Binding: AllLanguages
Observation.statusrequiredObservationStatus
Observation.categorypreferredObservationCategoryCodes
Observation.codeexampleLOINCCodes
Observation.code.coding:sctrequiredECGAtrioventricularBlock
Observation.dataAbsentReasonextensibleDataAbsentReason
Observation.interpretationextensibleObservationInterpretationCodes
Observation.bodySiteexamplePattern: SNOMED CT code 80891009("Heart structure (body structure)")
Observation.methodexampleObservationMethods
Observation.referenceRange.typepreferredObservationReferenceRangeMeaningCodes
Observation.referenceRange.appliesToexampleObservationReferenceRangeAppliesToCodes
Observation.component.codeexampleLOINCCodes
Observation.component.dataAbsentReasonextensibleDataAbsentReason
Observation.component.interpretationextensibleObservationInterpretationCodes

Constraints

IdPathDetailsRequirements
value-or-data-absent-reasonObservationIf there is no a value a data absent reason must be present or vice versa
: value.exists() or dataAbsentReason.exists()
obs-3Observation.referenceRangeMust have at least a low or a high or text
: low.exists() or high.exists() or text.exists()