Breast Cancer Specification
0.1.0 - ci-build
Breast Cancer Specification - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
<Specimen xmlns="http://hl7.org/fhir">
<id value="IntegratedSLNSpecimenPart"/>
<meta>
<profile
value="https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/StructureDefinition/mii-pr-patho-specimen|2026.0.0"/>
<profile
value="https://www.medizininformatik-initiative.de/fhir/ext/modul-biobank/StructureDefinition/SpecimenCore|2026.0.0"/>
</meta>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: Specimen IntegratedSLNSpecimenPart</b></p><a name="IntegratedSLNSpecimenPart"> </a><a name="hcIntegratedSLNSpecimenPart"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px"/><p style="margin-bottom: 0px">Profiles: <a href="https://simplifier.net/resolve?scope=de.medizininformatikinitiative.kerndatensatz.patho@2026.0.0&canonical=https://www.medizininformatik-initiative.de/fhir/ext/modul-patho/StructureDefinition/mii-pr-patho-specimen">MII PR Patho Specimen</a> version: 2026.0.0, <a href="https://simplifier.net/resolve?scope=de.medizininformatikinitiative.kerndatensatz.onkologie@2026.0.0&canonical=https://www.medizininformatik-initiative.de/fhir/ext/modul-biobank/StructureDefinition/SpecimenCore">MII PR Biobank Specimen Bioprobe Core</a> version: 2026.0.0</p></div><p><b>identifier</b>: Placer Identifier/OP25_300_B, Filler Identifier/E_25_300_B</p><p><b>accessionIdentifier</b>: <code>https://pathologie.example-hospital.de/fhir/fn/befundbericht</code>/E_25_300</p><p><b>status</b>: Available</p><p><b>type</b>: <span title="Codes:{http://snomed.info/sct 258589002}">Lymph node specimen (specimen)</span></p><p><b>subject</b>: <a href="Patient-Patient4.html">Sabine Becker Female, DoB: 1971-03-15 ( http://example.hospital.de/patient-ids#PAT-2025-105)</a></p><p><b>request</b>: <a href="ServiceRequest-IntegratedReportRequest.html">ServiceRequest Pathology synoptic report</a></p><h3>Collections</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Collector</b></td><td><b>Collected[x]</b></td><td><b>Method</b></td><td><b>BodySite</b></td></tr><tr><td style="display: none">*</td><td><a href="Practitioner-BreastSurgeonPractitioner.html">Practitioner Thomas Richter </a></td><td>2025-02-05 10:30:00+0100</td><td><span title="Codes:{http://snomed.info/sct 396487001}">Sentinel lymph node biopsy (procedure)</span></td><td><span title="Codes:{http://snomed.info/sct 68171009}">Axillary lymph node structure (body structure)</span></td></tr></table><h3>Containers</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Type</b></td><td><b>Additive[x]</b></td></tr><tr><td style="display: none">*</td><td><span title="Codes:{http://snomed.info/sct 434746001}">Specimen vial (physical object)</span></td><td><span title="Codes:{http://snomed.info/sct 434162003}">Neutral buffered formalin (substance)</span></td></tr></table><p><b>note</b>: </p><blockquote><div><p>Sentinel-Lymphknoten-Exzisat linke Axilla, 2 SLN identifiziert (Patentblau-markiert). SLN #1: 12 x 8 x 6 mm, SLN #2: 10 x 7 x 5 mm. Beide halbiert und vollständig eingebettet.</p>
</div></blockquote></div>
</text>
<identifier>
<type>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0203"/>
<code value="PLAC"/>
</coding>
</type>
<system
value="https://senologie.example-hospital.de/fhir/specimen/placer"/>
<value value="OP25_300_B"/>
</identifier>
<identifier>
<type>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0203"/>
<code value="FILL"/>
</coding>
</type>
<system
value="https://pathologie.example-hospital.de/fhir/fn/befundbericht"/>
<value value="E_25_300_B"/>
</identifier>
<accessionIdentifier>
<system
value="https://pathologie.example-hospital.de/fhir/fn/befundbericht"/>
<value value="E_25_300"/>
</accessionIdentifier>
<status value="available"/>
<type>
<coding>
<system value="http://snomed.info/sct"/>
<code value="258589002"/>
<display value="Lymph node specimen (specimen)"/>
</coding>
</type>
<subject>🔗
<reference value="Patient/Patient4"/>
</subject>
<request>🔗
<reference value="ServiceRequest/IntegratedReportRequest"/>
</request>
<collection>
<collector>🔗
<reference value="Practitioner/BreastSurgeonPractitioner"/>
</collector>
<collectedDateTime value="2025-02-05T10:30:00+01:00"/>
<method>
<coding>
<system value="http://snomed.info/sct"/>
<code value="396487001"/>
<display value="Sentinel lymph node biopsy (procedure)"/>
</coding>
</method>
<bodySite>
<coding>
<system value="http://snomed.info/sct"/>
<code value="68171009"/>
<display value="Axillary lymph node structure (body structure)"/>
</coding>
</bodySite>
</collection>
<container>
<type>
<coding>
<system value="http://snomed.info/sct"/>
<code value="434746001"/>
<display value="Specimen vial (physical object)"/>
</coding>
</type>
<additiveCodeableConcept>
<coding>
<system value="http://snomed.info/sct"/>
<code value="434162003"/>
<display value="Neutral buffered formalin (substance)"/>
</coding>
</additiveCodeableConcept>
</container>
<note>
<text
value="Sentinel-Lymphknoten-Exzisat linke Axilla, 2 SLN identifiziert (Patentblau-markiert). SLN #1: 12 x 8 x 6 mm, SLN #2: 10 x 7 x 5 mm. Beide halbiert und vollständig eingebettet."/>
</note>
</Specimen>